7 warning signs your gas turbine compressor needs cleaning
02 Sept 2026
ROCHEM Fyrewash Ltd
5-6 Sun Valley Business Park
Winnall Close, Winchester
Hampshire
SO23 0LB
ROCHEM Fyrewash Inc
23707 West Hardy Road
Spring
Texas
77373

Subscribe to our newsletter for important news and updates.

02 Sept 2026
Gas turbine compressors suffer from foulant build-up: when contaminants from the air (and other sources) adhere to the blades, reducing internal volume, interrupting airflow, and corroding/eroding surfaces.
Cleaning your gas turbine compressor is essential to keep it running efficiently and extend its service life. But how do you know when to wash it?
Today we’re looking at the telltale signs your gas turbine compressor needs a clean, so you can stay ahead of the game in gas turbine maintenance and avoid costly unscheduled shutdowns.
Gas turbine compressor fouling is a gradual process as microscopic contaminants slowly accumulate. It’s very unlikely you’ll notice a significant, sudden reduction in power output, but rather a subtle decrease in performance over time. This means operators rarely get an obvious signal that something is wrong until equipment suddenly fails.
While the subtle decrease in output may seem unimportant, operators are forced to compensate by using more and more fuel to achieve the same results, and costs mount.
While the process is gradual, you shouldn’t ignore it. Keep a lookout for these telltale signs your gas turbine compressor needs cleaning and keep it as efficient as possible:
It’s important to keep track of your gas turbine’s performance. One of the earliest signs of gas compressor fouling is a gradual reduction in power. Power loss may be almost unnoticeable day to day, so review historical performance data to see whether output is dropping. Fouling could be the culprit, and it’s time to carry out a compressor wash.
Another sign of declining efficiency is a gradual increase in fuel consumption. As efficiency declines, you may use more fuel to generate the same power output.
Monitor fuel consumption to see if it’s creeping up. If so, a compressor wash could remove foulants, restore lost power, and reduce fuel consumption.
Increasing exhaust gas temperature can be an early indication of compressor deterioration and fouling. As the turbine is forced to work harder and harder to maintain output, the temperature increases. Keep a log and review it to see whether there are notable changes.
Look at changes in compressor efficiency, airflow, or pressure ratios, which are all useful indicators of compressor health. Even small changes can signal developing fouling, so it’s time to take action with a compressor wash.
While numerical data is extremely useful, you may be able to physically see foulant build-up. Observation windows give you a view to the inner workings of the gas turbine compressor, while routine inspections/borescope examinations can reveal contamination and other issues.

Visual inspections should not replace operational data, but they can help diagnose any noted power loss, increased fuel consumption, or higher-than-expected exhaust temperatures.
While it’s not exactly a sign, you should carefully consider your operating environment. Gas turbines operating in coastal, desert, industrial or offshore environments are generally exposed to higher levels of airborne contamination. Foulants tend to build up much more quickly than you might expect, and frequent compressor washing should be a default part of the maintenance schedule.
Finally, rather than relying on single measurements, it’s better to monitor performance trends over time. A downward curve in power output and a gradual increase in fuel consumption and exhaust temperature indicate deteriorating compressor performance. If so, it’s time for a wash.
Foulant build-up is gradual, so the best way to keep it under control is:
This three-pronged washing method keeps foulant build-up to a minimum while also combating stubborn deposits to keep your gas turbine compressor in peak condition. Experience shows this approach is much better and more cost-effective than waiting for obvious, significant performance deterioration or indeed equipment failure.

There’s a lot to think about when you’re responsible for the health and productivity of a gas turbine power site. While a well-managed cleaning schedule should keep your turbine compressor in good condition, watch for the telltale signs we’ve outlined to monitor cleanliness and maximize efficiency.
If you’re interested in introducing or improving gas turbine compressor washes, we’re here to help. Our specialized cleaning chemicals and equipment are backed by decades of industry experience and chosen at thousands of sites worldwide.
Please browse our product range and get in touch to see how we can help.

Post written by Martin Howarth
An extensive knowledge of mechanical and electrical engineering together with hands on experience with gas turbines provides a bedrock for his work at Rochem.